Key Specs

Emissions
EPA and CARB Non-Road Mobile Tier 2, IMO Tier II, China Stage III
EPA and CARB Non-Road Mobile Tier 2, IMO Tier II, China Stage III
Displacement
1960.5 in³
32.1 l
Length
76.18 in
1934.9 mm

Overview

Cat C32 ACERT engines are the ideal solution for your demanding operations in the oilfield. Decades of field operation and intense research and development allow Cat C32 ACERT engines to deliver excellent performance with low operating costs and emissions. Equipment powered by C32 ACERT engines include well stimulation pumping, pump skids, nitrogen units, acidizing units, blenders, and hydraulic power units. Cat engines are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty. Cat C32 ACERT Industrial Diesel Engine. Ratings: 597-1119 bkW (800-1500 bhp) @ 1800-2100 rpm meet U.S. EPA Tier 2 equivalent and China Stage III emission standards. They are available using U.S. EPA Flexibility, and for other regulated and non-regulated areas.

Product Specifications for C32 ACERT™ (Dry Manifold)

Emissions EPA and CARB Non-Road Mobile Tier 2, IMO Tier II, China Stage III EPA and CARB Non-Road Mobile Tier 2, IMO Tier II, China Stage III
Displacement 1960.5 in³ 32.1 l
Governor and Protection ADEM A3 ADEM A3
Aspiration Turbocharged-Aftercooled Turbocharged-Aftercooled
Flywheel and Flywheel Housing SAE No. 0 or SAE No. 1 SAE No. 0 or SAE No. 1
Flywheel Teeth 136 136
Rotation from Flywheel End Counterclockwise Counterclockwise
Stroke 6.4 in 162 mm
Bore 5.7 in 145 mm
Length 76.18 in 1934.9 mm
Width 56.34 in 1431 mm
Height 54.66 in 1388.3 mm
Weight 5040 lb 2286 kg
Cooling System 14.5 gal (US) 55 l

C32 ACERT™ (Dry Manifold) Standard Equipment

Air Inlet System

  • Connections configured for ATAAC (Air-to-Air-Aftercooled) or remote heat exchanger

Control System

  • ADEM A4 electronic control module
  • Electronic governing, PTO speed control
  • Customer programmable ratings
  • Cold mode start strategy
  • Automatic altitude compensation
  • Automatic fuel temperature compensation
  • Programmable low and high idle, and top engine speed limit
  • Electronic diagnostics and fault logging
  • Engine monitoring system
  • SAE J1939 broadcast (diagnostic and engine status)

Cooling System

  • Gear-driven centrifugal jacket water pump — RH
  • Integrated thermostat and housing
  • Engine oil cooler
  • Optional installed transmission oil cooler

Exhaust System

  • Exhaust manifold — dry
  • Two vertical exhaust outlets (front and rear)

Fuel System

  • MEUI
  • Fuel priming pump
  • Fuel transfer pump
  • Primary and secondary fuel filter — RH configured for remote mounting (installed RH on shipping plate)

Flywheels and Flywheel Housing

  • SAE No. 0 or SAE No. 1 flywheel iron housing
  • SAE No. 0 or SAE No. 1 flywheel
  • Optional transmission adapter

Lube System

  • Crankcase breather
  • Oil filter — RH standard, optional LH or remote mount service
  • Oil level gauge — RH standard, optional LH or dual service
  • Oil filler — RH standard, optional LH or dual service
  • Shallow oil pan, rear sump

Mounting System

  • Trunnion front support
  • Vertical and horizontal pads on rear flywheel housing

Protection System

  • 24V electronic
  • Engine overspeed with optional air shut-offs with indicators
  • Low engine oil pressure
  • Fuel filter restriction
  • Fuel temperature
  • High engine coolant temperature
  • Low engine coolant temperature

General

  • Vibration damper and optional guard
  • Lifting eyes
  • Optional customer wiring connector
  • Service tool connector
  • Paint — Cat yellow

C32 ACERT™ (Dry Manifold) Optional Equipment

Air Inlet System

  • Air cleaner
  • Air inlet adapters
  • Turbocharger outlet adapters
  • Air lines

Charging System

  • Battery chargers
  • Charging alternators
  • Alternator mounting
  • Circuit breakers and mountings

Cooling System

  • Dry charge coolant conditioners
  • Thermostat housing
  • Coolant level sensor
  • Radiator
  • Blower fans
  • Suction fans
  • Fan adapters
  • Fan drives

Emissions

  • IMO certifications

Exhaust System

  • Elbows
  • Mufflers

Fuel Systems

  • Electric fuel priming pump

Instrumentation

  • Customer management device
  • Interconnect harness
  • Gauges and instrument panels

Lube System

  • Oil pans
  • Oil service side
  • Oil level gauge
  • Oil filters
  • Lubricating oils

Mounting System

  • Structural steel base
  • Engine support — front
  • Engine support — rear

Power Take-Offs

  • Auxiliary drive
  • Damper pulley
  • Hydraulics gear pumps

Protection System

  • Mechanical shutoffs
  • Solenoid shutoffs

Starting System

  • Electric starting motors - 12V, 24V
  • Battery sets - 24V
  • Battery cable
  • Battery rack
  • Starting aids

Transmission Arrangement

  • Transmissions water lines
  • Transmissions cooler

See how C32 ACERT™ (Dry Manifold) compares against frequently compared products.

Tools And Expert Help At Every Turn

Product Brochures and More Are Ready to Download!

Full specifications, product brochures and more. Sign up below for additional information. Or for instant access, you can skip this form.

By sharing your information you’re giving Caterpillar permission to process your data to appropriately fulfill your request. Depending on your request, we may need to share your data with applicable dealers, within the Caterpillar group of companies, and applicable service providers operating on Caterpillar's behalf. Taking care of your information is a responsibility we take seriously. Our Website Privacy Notice details our data privacy practices and your rights to control your personal data.

*Marketing Consent

Check out current offers for the C32 ACERT™ (Dry Manifold)

View More Offers