CG260-16 4500 kW

Gas Generator Sets CG260-16

Request A Price Find Dealer

Key Specs

Continuous Rating
4500 / 4050 ekW @1.0pf
4500 / 4050 ekW @1.0pf
Fuel Type
Natural Gas, Hydrogen Blend (up to 25%)
Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency
44.60 / 44.3%
44.60 / 44.3%

Overview

4500 KW Generator Set

From natural gas-fueled combined heat and power (CHP) systems and emergency power for facilities, to renewable biogas energy to support the local grid, or electricity generated from coal mine gases, Caterpillar has a wide range of reliable gas power solutions.

Benefits

Up to 25% hydrogen blended fuel option

Enables operation of up to 25% hydrogen blend (by volume) with pipeline natural gas fuel.

Product Specifications for CG260-16

Continuous Rating 4500 / 4050 ekW @1.0pf 4500 / 4050 ekW @1.0pf
Fuel Type Natural Gas, Hydrogen Blend (up to 25%) Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency 44.60 / 44.3% 44.60 / 44.3%
Maximum Standby Rating 4500 ekW 4500 ekW
Frequency 50 / 60 Hz 50 / 60 Hz
RPM 1000 / 900 rpm 1000 / 900 rpm
Length 371 in 9420 mm
Width 110 in 2794 mm
Height 133 in 3390 mm
Dry Weight - Genset 117505 lb 53299.4 kg
Engine Model CG260-16 CG260-16
Displacement 16586 in³ 271.8 l
Stroke 12.6 in 320 mm
Bore 10.2 in 260 mm
Aspiration TA TA

CG260-16 Standard Equipment

Air Inlet

  • One-element single-stage air cleaner with enclosure and sevice indicator
  • Turbocharger with a water-cooled bearing case for all cylinder

Control Panels

  • TEM (Total Electronic Management)

Cooling

  • flange connections for JW inlet and outlet
  • Jacket water and SCAC thermostats
  • Electrical jacket water and aftercooler coolant pump

Exhaust

  • Closed crankcase ventilation system
  • Exhaust waste gate for the CG260-16

Fuel system

  • Pre-chamber spark plugs
  • Independently controlled cylinder monitoring and ignition system
  • Electronic fuel metering valve

Generator

  • Reactive droop
  • 3-phase sensing and KVAR/PF control
  • Winding temperature detectors
  • Grid code generator
  • Anti-condensation space heater
  • Closed-coupled generator result in no torque transmission to the base frame
  • Busbar connections

Starting/Charging

  • Compressed air engine start

General

  • Crankshaft vibration damper and guard

CG260-16 Optional Equipment

Cooling

  • CHP skid

Grid Code Compliance

  • 50Hz: Germany, Belgium, Great Britain, Italy, Poland, and Netherlands

See how CG260-16 compares against frequently compared products.

Use the comparison tool to compare detailed specs of Cat and competitor models.

Compare All Models

Media Gallery

CG260-16

CG260-16

360 View

Check out current offers for the CG260-16